Control panel calibration issue

Control panel calibration issue

Control Panel Calibration Issue on Lexmark X548, X79x, X92x, X95x,&6500 MFPs
What you will see
When you press buttons or keys on the touchscreen panel, the device tends to show a
different area
,
key
, or
button
than the one you selected, one that is
above
the actual area pressed. Alternatively, it can appear that the button is being pressed but nothing is selected. This latter issue happens for buttons such as "
Home
" and "
Submit
", where there is not another button immediately above.
NOTE:
This calibration issue is
less
severe as you go to the top of the control panel.
See sample video below.

Please allow time for the video to load. You will need Quicktime to view the above video. Click
to download Quicktime now.
Recommended Action
A
sagging
touch screen can cause this panel calibration issue, which can occur if the foam spacer between the touch screen and the LCD becomes too loose. Thus, when you touch a portion of the touch screen, you actually interact with the area corresponding to the LCD point above the one you touched.
To determine whether the panel calibration issue is caused by a
sagging
touch screen, put your finger on the middle of the touch screen. Press and hold the screen, then slowly move the screen physically up and down. If the touch screen moves then the
Operator Panel Assembly
needs to be replaced. Please contact
Lexmark Technical Support
or a local authorized service provider for additional assistance.
NOTE:
If the panel calibration issue is
not
caused by a
sagging
touch screen, please proceed with the
Recommended Solution
below.
Recommended Solution
Update the printer’s firmware to
EC4
or the
latest
.
LEGACY ID:
TE599
Technical Service Bulletin
Problem Description
Machine Type/Model
Lexmark Models: X548 7525-63X X792 7562-4XX C925 5041-03X X95x 7558-xxx 6500 MFPs 4036-31X
When customer presses a
button
or
key
on the control panel, another area is pressed instead.
Solution
Issue is caused either by a
sagging
touch screen or a firmware issue.
Replace the Operator panel assembly if necessary or update the printer with
EC4
or the
latest
firmware code.
Date Created
04/14/2014
Last Updated
05/11/2017
Safety Issue?
No
Code Update?
No
Engineering Change?
Yes
New Parts?
No
Old Parts Status
n/a