Thank you for your feedback



Lexmark Security Advisory: Cross Site Scripting vulnerabilities (CVE-2019-19772, CVE-2019-19773)

Document ID:TE935

Usergroup :External
  Languages  
  Properties  

Solution

Lexmark Security Advisory:

 Revision:  1.0
 Last update:     20 February 2020
 Public Release Date:  28 February 2020

 

 

Summary

 
Two Cross Site Scripting vulnerabilities have been identified in older Lexmark devices.

 

 

References

 
CVE: CVE-2019-19772, CVE-2019-19773

 

 

Details

CVE-2019-19772

A reflected cross site scripting vulnerability has been identified in the embedded web server used in older
generation Lexmark devices. The vulnerability can be used to attack the user’s browser, exposing session
credentials and other information accessible to the browser.
 

CVSSv3.1 Base Score 5.7 (AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N)
Impact Subscore: 3.6  
Exploitability Subscore: 2.1  

 

CVE-2019-19773

A stored cross site scripting vulnerability has been identified in the embedded web server used in older
generation Lexmark devices. The vulnerability can be used to attack the user’s browser, exposing session
credentials and other information accessible to the browser.
 

CVSSv3.1 Base Score 5.7 (AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N)
Impact Subscore: 3.6  
Exploitability Subscore: 2.1  

 

CVSSv3 scores are calculated in accordance with CVSS version 3.1 (https://www.first.org/cvss/user-guide)

 

Impact
 

Successful exploitation of this vulnerability can lead to disclosure of information accessible to the browser,
including session hijacking and credential theft.

 

 

Affected Products

 
To determine a devices firmware level, select the Settings > Reports > Menu Setting Page menu item from the operator panel.
If the firmware level listed under “Device Information” matches any level under “Affected Releases”, then upgrade to a “Fixed Release”.


Lexmark Models Affected Releases Fixed Releases
CS31x LW74.VYL.P267 and previous LW74.VYL.P268 and later
CS41x LW74.VY2.P267 and previous LW74.VY2.P268 and later
CS51x LW74.VY4.P267 and previous LW74.VY4.P268 and later
CX310 LW74.GM2.P267 and previous LW74.GM2.P268 and later
CX410 & XC2130 LW74.GM4.P267 and previous LW74.GM4.P268 and later
CX510 & XC2132 LW74.GM7.P267 and previous LW74.GM7.P268 and later
MS310, MS312, MS317 LW74.PRL.P267 and previous LW74.PRL.P268 and later
MS410, M1140 LW74.PRL.P267 and previous LW74.PRL.P268 and later
MS315, MS415, MS417 LW74.TL2.P267 and previous LW74.TL2.P268 and later
MS51x, MS610dn, MS617 LW74.PR2.P267 and previous LW74.PR2.P268 and later
M1145, M3150dn LW74.PR2.P267 and previous LW74.PR2.P268 and later
MS610de, M3150 LW74.PR4.P267 and previous LW74.PR4.P268 and later
MS71x,M5163dn LW74.DN2.P267 and previous LW74.DN2.P268 and later
MS810, MS811, MS812, MS817, MS818 LW74.DN2.P267 and previous LW74.DN2.P268 and later
MS810de, M5155, M5163 LW74.DN4.P267 and previous LW74.DN4.P268 and later
MS812de, M5170 LW74.DN7.P267 and previous LW74.DN7.P268 and later
MS91x LW74.SA.P267 and previous LW74.SA.P268 and later
MX31x, XM1135 LW74.SB2.P267 and previous LW74.SB2.P268 and later
MX410, MX510 & MX511 LW74.SB4.P267 and previous LW74.SB4.P268 and later
XM1140, XM1145 LW74.SB4.P267 and previous LW74.SB4.P268 and later
MX610 & MX611 LW74.SB7.P267 and previous LW74.SB7.P268 and later
XM3150 LW74.SB7.P267 and previous LW74.SB7.P268 and later
MX71x, MX81x LW74.TU.P267 and previous LW74.TU.P268 and later
XM51xx & XM71xx LW74.TU.P267 and previous LW74.TU.P268 and later
MX91x & XM91x LW74.MG.P267 and previous LW74.MG.P268 and later
MX6500e LW74.JD.P267 and previous LW74.JD.P268 and later
C746 LHS60.CM2.P731 and previous LHS60.CM2.P736 and later
C748, CS748 LHS60.CM4.P735 and previous LHS60.CM4.P736 and later
C792, CS796 LHS60.HC.P735 and previous LHS60.HC.P736 and later
C925 LHS60.HV.P735 and previous LHS60.HV.P736 and later
C950 LHS60.TP.P735 and previous LHS60.TP.P736 and later
X548 & XS548 LHS60.VK.P735 and previous LHS60.VK.P736 and later
X74x & XS748 LHS60.NY.P735 and previous LHS60.NY.P736 and later

X792 & XS79x

LHS60.MR.P735 and previous LHS60.MR.P736 and later
X925 & XS925 LHS60.HK.P735 and previous LHS60.HK.P736 and later
X95x & XS95x LHS60.TQ.P735 and previous LHS60.TQ.P736 and later
6500e LHS60.JR.P735 and previous LHS60.JR.P736 and later
C734 LR.SK.P822 and previous Contact Lexmark
C736 LR.SKE.P822 and previous Contact Lexmark
E46x LR.LBH.P822 and previous Contact Lexmark
T65x LR.JP.P822 and previous Contact Lexmark
X46x LR.BS.P822 and previous Contact Lexmark
X65x  LR.MN.P822 and previous Contact Lexmark
X73x LR.FL.P822 and previous Contact Lexmark
W850 LP.JB.P821 and previous Contact Lexmark
X86x LP.SP.P821 and previous Contact Lexmark

 

 

Obtained Updated Software


To obtain firmware that resolves this issue or if you have special code, please contact Lexmark’s Technical
Support Center at http://support.lexmark.com to find your local support center.

 

 

Workarounds


The XSS vulnerabilities may be mitigated by disabling the Embedded Web Server (EWS) in the affected devices.

Lexmark recommends a firmware update if your device has affected firmware.

 

 

Exploitation and Public Announcements


Lexmark is not aware of any malicious use against Lexmark products of the vulnerability described in this advisory.

Lexmark would like to thank Vidya Bhaskar Tripathi for bringing this to our attention.

 

 

 

Status of this Notice:


THIS DOCUMENT IS PROVIDED ON AN "AS IS" BASIS AND IS PROVIDED WITHOUT ANY EXPRESS OR IMPLIED GUARANTEE OR WARRANTY WHATSOEVER, INCLUDING BUT NOT LIMITED TO
THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE OR PURPOSE. LEXMARK RESERVES THE RIGHT TO CHANGE OR UPDATE THIS DOCUMENT AT ANY TIME.

 

  

Distribution


This advisory is posted on Lexmark’s web site at http://support.lexmark.com/alerts.
Future updates to this document will be posted on Lexmark’s web site at the same location.

 

 

Revision History

 

Revision Date Reason
1.0 20 - February - 2020 Initial Public Release

 

 Top