Thank you for your feedback



How to Set Termination on the OptraImage 2x2 and 4x3 Scan Units

Document ID:HO576
 
  Properties  

Problem

v3.9v message on scanner

Environment

How to set termination on the OptraImage 2x2 and 4x3 scan units; Scanner; SCSI termination

Solution

Purpose

Termination is required in order for all SCSI devices on the SCSI bus to communicate with one another. Each "end" of the SCSI bus MUST be terminated.

Method

Each scan unit has two DIP switch panels on the back. Proper termination is achieved when all four DIP switches are down on the left panel and when the first and fourth DIP switches are down on the right panel. 

Illustration:


Left - All down; Right - Down, Up, Up, Down

Additional Suggestions
  • If the scanner continues to display v3.9 after you have checked the DIP switch configuration, reconnect the 50-pin SCSI cable to both scanner and Fax/SCSI ethernet card. Be sure to check for damage to any of the pins on this cable. 
  • Print out to the Fax/SCSI ethernet page to confirm that both panel and scanner are being recognized. For example:

  • Device ID, Revision Name: 0, 3.9V Lexmark OptraImage Panel
  • Device ID, Revision Name: 6, 1.07 Lexmark OptraImage 2X2   

Contacting Lexmark

If you need additional assistance, please contact Lexmark Technical Support. NOTE: When calling for support, you will be asked for your machine/model type and serial number (SN).
Please call from near the router, computer, and printer in case the technician on the phone asks you to perform a task involving one or all of these devices.